The NDM3A-630 molded case circuit breaker (hereinafter referred to as circuit breaker) appliesto infrequent switching of circuits with the AC 50/60Hz, the working voltage of AC1000V and working current of 630A as well as infrequent motor starting. With the overload, short circuit and undervoltage protection functions, the circuit breaker can protect lines and power equipment from damage.
Normal Working Environment 1)The altitude of the installation site doesn’t exceed 2,500m. See the “High-altitude DeratingFactor Table of Circuit Breaker” for the derating factor at the altitude; 2)The ambient temperature is -35℃ ~ + 70℃; the average within 24 h shall not be morethan +35℃. If the ambient temperature is higher than +40℃, the user needs to reduce thecapacity. See the “Derating Factor Table of Temperature Change for the Circuit Breaker”for the derating factor; 3)Its relative humidity at an ambient temperature of +40℃ should not exceed 50%. A higherrelative humidity is allowed at a lower temperature. For example, the relative humidity at20℃ can reach 90%; for frost due to temperature change, the corresponding measuresshould be taken; 4)The product can withstand the effects of wet air, salt mist, oil mist and mould; 5)The installation category of the circuit breaker connected to the main loop is: Category Ⅲ (power distribution and control level), The installation category of the circuit breaker notconnected to the main loop is: Category Ⅱ (load level); 6)The pollution level is Level 3; 7)The product should be installed in places that are free from explosive media, mediacorrosive to metal, insulation damaging gas, and conductive dust, which should be alsoavoided from snow and rain; 8)In case of stricter user conditions than the above description, negotiate with themanufacturer.
Circuit Breaker Applicab1e scope and purpose NDB6AZ-63H series circuit breakers products are mainly used in telecommunications equipment rooms or communication cabinets,as isolation,short circuit and overload protection f...
NDB3-50 is a hydraulic-magnetic circuit breaker for equipment, designed to protect AC and DC control circuits against overload and short circuit. Its modular options support a wide range of equipment and installation requirements. Typical configu...
1.Application NDB1-125 series is used in low voltage electrical distribution system in industry, real estate, power, telecom, construction field, etc. 2.Specification 3.Working conditions: 4.Packing and depositing:
Outdoor Solution, also known as a NEMA 3R Outdoor Power Distribution Solution, is a customized electrical distribution system designed for outdoor installation. It is used to receive, transform, distribute, protect, and control electrical power in...